Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Front Cardiovasc Med ; 10: 1215826, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38034386

RESUMEN

Background: Up to one-fifth of patients continue to have poor quality of life after transcatheter aortic valve implantation (TAVI), with an additional similar proportion not surviving 1 year after the procedure. We aimed to assess the value of a new method based on an integrated analysis of left ventricular outflow tract flow velocity and aortic pressure to predict objective functional improvement and prognosis after TAVI. Methods: In a cohort of consecutive patients undergoing TAVI, flow velocity-pressure integrated analysis was obtained from simultaneous pressure recordings in the ascending aorta and flow velocity recordings in the left ventricular outflow tract by echocardiography. Objective functional improvement 6 months after TAVI was assessed through changes in a 6-min walk test and NT-proBNP levels. A clinical follow-up was conducted at 2 years. Results: Of the 102 patients studied, 82 (80.4%) showed objective functional improvement. The 2-year mortality of these patients was significantly lower (9% vs. 44%, p = 0.001). In multivariate analysis, parameter "(Pressure at Vmax - Pressure at Vo)/Vmax" was found to be an independent predictor for objective improvement. The C-statistic was 0.70 in the overall population and 0.78 in the low-gradient subgroup. All echocardiographic parameters and the valvuloarterial impedance showed a C-statistic of <0.6 for the overall and low-gradient patients. In a validation cohort of 119 patients, the C-statistic was 0.67 for the total cohort and 0.76 for the low-gradient subgroup. Conclusion: This new method allows predicting objective functional improvement after TAVI more precisely than the conventional parameters used to assess the severity of aortic stenosis, particularly in low-gradient patients.

2.
Artículo en Inglés, Español | MEDLINE | ID: mdl-38000627

RESUMEN

INTRODUCTION AND OBJECTIVES: There are scarce data on the factors associated with impaired functional status after transcatheter aortic valve replacement (TAVR) and its clinical impact. This study aimed to determine the incidence, predictors, and prognostic implications of impaired functional class (NYHA class III-IV) following TAVR. METHODS: This multicenter study included 3462 transarterial TAVR patients receiving newer generation devices. The patients were compared according to their NYHA class at 1 month of follow-up (NYHA I-II vs NYHA III-IV). A multivariate logistic regression was performed to identify the predictors of 30-day NYHA class III-IV. Patient survival was compared with the Kaplan-Meier method and factors associated with decreased survival were identified with Cox regression analysis. RESULTS: The mean age of the study population was 80.3±7.3 years, with 47% of women, and a median Society of Thoracic Surgeons score of 3.8% [IQR, 2.5-5.8]. A total of 208 patients (6%) were in NYHA class III-IV 1 month after TAVR. Predictors of 30-day NYHA class III-IV were baseline NYHA class III-IV (OR, 1.76; 95%CI, 1.08-2.89; P=.02), chronic pulmonary obstructive disease (OR, 1.80; 95%CI, 1.13-2.83; P=.01), and post-TAVR severe mitral regurgitation (OR, 2.00; 95%CI, 1.21-3.31; P<.01). Patients in NYHA class III-IV 1 month after TAVR were at higher risk of death (HR, 3.68; 95%CI, 2.39-5.70; P<.01) and heart failure-related hospitalization (HR, 6.00; 95%CI, 3.76-9.60; P<.01) at 1-year follow-up. CONCLUSIONS: Up to 6% of contemporary TAVR patients exhibited an impaired functional status following TAVR. Worse baseline NYHA class, chronic pulmonary obstructive disease, and severe mitral regurgitation predicted 30-day NYHA class III/IV, and this determined a higher risk of mortality and heart failure hospitalization at 1-year follow-up. Further studies on the prevention and treatment optimization of patients with impaired functional status after TAVR are needed.

3.
PeerJ ; 11: e16102, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37780383

RESUMEN

Background: Aortic valve stenosis (AVS) affects 25% of the population over 65 years. At present, there is no curative medical treatment for AVS and therefore the surgical approach, consisting of transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR), is the treatment of choice. Methodology: The aim of this study was to analyze the sociodemographic and clinical characteristics, quality of life and functionality of a sample of patients with AVS over 75 years of age, who underwent TAVR or SAVR, applying standard clinical practice. A prospective multicenter observational study was conducted in two hospitals of the Spanish National Health System. Data were collected at baseline, 1, 6 months and 1 year. Results: In total, 227 participants were included, with a mean age of 80.6 [SD 4.1]. Statistically significant differences were found in terms of quality of life, which was higher at 1 year in patients who underwent SAVR. In terms of functionality, SAVR patients obtained a better score (p < 0.01). However, patients who underwent TAVR began with a worse baseline situation and managed to increase their quality of life and functionality after 1 year of follow-up. Conclusion: The individualized choice of TAVR or SAVR in patients with AVS improves patients' quality of life and function. Moreover, the TAVR procedure in patients with a worse baseline situation and a high surgical risk achieved a similar increase in quality of life and functionality compared to patients undergoing SAVR with a better baseline situation.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Calidad de Vida , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Prospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/epidemiología
4.
JACC Cardiovasc Interv ; 16(18): 2277-2290, 2023 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-37758382

RESUMEN

BACKGROUND: The burden of cardiac death after transcatheter aortic valve replacement (TAVR), particularly from advanced heart failure (HF) and sudden cardiac death (SCD), remains largely unknown. OBJECTIVES: This study sought to evaluate the incidence and predictors of SCD and HF-related death in TAVR recipients treated with newer-generation devices. METHODS: This study included a total of 5,421 consecutive patients who underwent TAVR with newer-generation devices using balloon (75.7%) or self-expandable (24.3%) valves. RESULTS: After a median follow-up of 2 (IQR: 1-3) years, 976 (18.0%) patients had died, 50.8% from cardiovascular causes. Advanced HF and SCD accounted for 11.6% and 7.5% of deaths, respectively. Independent predictors of HF-related death were atrial fibrillation (HR: 2.17; 95% CI: 1.47-3.22; P < 0.001), prior pacemaker (HR: 1.79; 95% CI: 1.10-2.92; P = 0.01), reduced left ventricular ejection fraction (HR: 1.08 per 5% decrease; 95% CI: 1.01-1.14; P = 0.02), transthoracic approach (HR: 2.50; 95% CI: 1.37-4.55; P = 0.003), and new-onset persistent left bundle branch block (HR: 1.85; 95% CI: 1.14-3.02; P = 0.01). Two baseline characteristics (diabetes, HR: 1.81; 95% CI: 1.13-2.89; P = 0.01; and chronic kidney disease, HR: 1.72; 95% CI: 1.02-2.90; P = 0.04) and 3 procedural findings (valve in valve, HR: 2.17; 95% CI: 1.01-4.64; P = 0.04; transarterial nontransfemoral approach, HR: 2.23; 95% CI: 1.23-4.48; P = 0.01; and periprocedural ventricular arrhythmia, HR: 7.19; 95% CI: 2.61-19.76; P < 0.001) were associated with an increased risk of SCD after TAVR. CONCLUSIONS: Advanced HF and SCD accounted for a fifth of deaths after TAVR in contemporary practice. Potentially treatable factors leading to increased risk of HF deaths and SCD were identified, such as arrhythmia/dyssynchrony factors for HF and valve-in-valve TAVR or periprocedural ventricular arrhythmias for SCD.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Volumen Sistólico , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Función Ventricular Izquierda , Resultado del Tratamiento , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
5.
Catheter Cardiovasc Interv ; 101(7): 1214-1220, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37125605

RESUMEN

OBJECTIVES: We sought to investigate the effect of a 15-min delayed intraprocedural reassessment of paravalvular aortic regurgitation (PVR) after an immediate evaluation of posttranscatheter aortic valve replacement (TAVR) on the regurgitation grading and usage of postdilatation. BACKGROUND: PVR after TAVR is associated with poor prognosis, but postdilatation may increase the risk of other complications. METHODS: In a prospective cohort of consecutive patients treated with balloon-expandable valve ES-3 ultra, the degree of PVR was assessed immediately and 15 min after that first evaluation (excluded severe cases), with the indication of postdilatation based on the delayed assessment. As a control group, the previous consecutive series of patients also treated with the same model of valve prosthesis was used. RESULTS: A total of 180 patients were included in the prospective study cohort and 152 in the retrospective control group. In the study group, the immediate PVR assessment showed none-trace 27.5%, mild 52%, moderate 19%, and severe 1.5%, and the delayed re-evaluation graded PVR as none-trace 83%, mild 15.6%, and moderate 1.2% (p < 0.001 as compared to immediate). In the control group, the immediate PVR assessment showed none-trace 33.5%, mild 52%, moderate 13%, and severe 1.5%. The rate of postdilatation was 2.8% in the study group versus 10.5% in the control group (p = 0.006). At discharge, no differences were observed between groups in PVR echocardiographic grading. CONCLUSIONS: A post-TAVR delayed intraprocedural reassessment of the PVR shows a clearly lower degree of regurgitation as compared to immediate evaluation, which significantly decreased the indication of postdilatation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Prospectivos , Prótesis Valvulares Cardíacas/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad
6.
Front Cardiovasc Med ; 10: 1118409, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36937938

RESUMEN

Background: A non-negligible rate of patients undergoing transcatheter aortic valve replacement (TAVR) do not report symptomatic improvement or even die in the short-midterm. We sought to assess the degree of objective functional recovery after TAVR and its prognostic implications and to develop a predictive model. Methods: In a cohort of patients undergoing TAVR, a prospective evaluation of clinical, anatomical, and physiological parameters was conducted before and after the procedure. These parameters were derived from echocardiography, non-invasive analysis of arterial pulse waves, and cardiac tomography. Objective functional improvement 6 months after TAVR was assessed using a 6-min walk test and nitro-terminal pro-brain natriuretic peptide (NT-proBNP) levels. The derived predictive model was prospectively validated in a different cohort. A clinical follow-up was conducted at 2 years. Results: Among the 212 patients included, objective functional improvement was observed in 169 patients (80%) and subjective improvement in 187 (88%). Patients with objective functional improvement showed a much lower death rate at 2 years (9% vs. 31% p = 0.0002). Independent predictors of improvement were as follows: mean aortic gradient of ≥40 mmHg, augmentation index75 of ≥45%, the posterior wall thickness of ≤12 mm, and absence of atrial fibrillation. A simple integer-based point score was developed (GAPA score), which showed an area under the curve of 0.81 for the overall cohort and 0.78 for the low-gradient subgroup. In a validation cohort of 216 patients, these values were 0.75 and 0.76, respectively. Conclusion: A total of 80% of patients experienced objective functional improvement after TAVR, showing a significantly lower 2-year mortality rate. A predictive score was built that showed a good discriminative performance in overall and low-gradient populations.

7.
Circ Cardiovasc Interv ; 16(3): e012554, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36943930

RESUMEN

BACKGROUND: The potential benefit of using larger or smaller transcatheter heart valves (THV) in patients with borderline aortic annulus measurement (BAM) remains uncertain. The objective of this study was to evaluate the clinical outcomes associated with the selection of larger or smaller THV in the context of BAM. METHODS: This was a multicenter observational study including patients who underwent transcatheter aortic valve replacement with the SAPIEN 3 or SAPIEN 3 Ultra-valve systems (Edwards Lifesciences, Irvine, CA) from April 2014 to June 2021. BAM was defined according to the manufacturer sizing chart and included the following annulus areas: 314 to 346, 400 to 430, 500 to 546 mm2. A 1:1 propensity score matching was used to compare outcomes of patients with larger or smaller THV. RESULTS: From a total of 2467 patients, BAM was identified in 852 patients (34.5%). A larger and smaller THV was selected in 338 (39.7%) and 514 patients (60.3%) patients, respectively. The choice of a larger THV was associated (before and after propensity matching) with a higher risk of new-onset left bundle branch block (HR, 2.25 [95% CI, 1.39-3.65; P=0.001) and permanent pacemaker implantation (HR, 1.86 [95% CI, 1.11-3.09]; P=0.016) without any impact on gradients or the risk of moderate or severe paravalvular regurgitation at discharge (HR, 0.78 [95% CI, 0.41-1.45]; P=0.427). The risk of periprocedural complications such as aortic rupture and tamponade was low (<1%) and similar between groups. CONCLUSIONS: In patient with BAM, selecting a larger SAPIEN 3/Ultra THV increased the risk of conduction disturbances without any benefit on valve hemodynamics and clinical outcomes.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de Prótesis
8.
J Invasive Cardiol ; 33(8): E604-E613, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34338651

RESUMEN

BACKGROUND: Vascular and bleeding complications related to secondary femoral access site are frequent in patients undergoing transcatheter aortic valve replacement (TAVR), and their occurrence is associated to poorer outcomes. We aimed to evaluate the clinical impact of vascular closure devices (VCDs) for secondary femoral access hemostasis in TAVR procedures. METHODS: This was a multicenter study including 4031 patients who underwent TAVR (mean age, 81 ± 8 years; mean Society of Thoracic Surgeons [STS] score, 4.9 [interquartile range, 3.3-7.6]), and had a secondary femoral access. The 30-day clinical outcomes were analyzed according to femoral access-site hemostasis (manual compression vs VCD), and according to the type of VCD (Perclose [Abbott Cardiovascular] vs Angio-Seal [Terumo Interventional Systems]) using a propensity-matched, multivariable, logistic regression model. RESULTS: Manual compression was used in 941 patients (23.3%) and VCDs were used in 3090 patients (76.7%; Perclose in 1549 patients [38.4%] and Angio-Seal in 1541 patients [38.2%]) for secondary femoral access hemostasis. Vascular complications related to secondary access site occurred in 162 patients (4%), and were more frequent in patients who underwent manual compression (7.2%) compared with VCD hemostasis (3%; adjusted P<.001). In the VCD group, the use of Angio-Seal (vs Perclose) was associated with a higher rate of vascular complications (3.7% vs 2.4%, respectively; adjusted P=.02), femoral artery pseudoaneurysm (1.3% vs 0.4%, respectively; adjusted P<.01), invasive treatment requirement for treating vascular complications (surgery: 0.8% vs 0.3%, respectively [adjusted P=.03]; and thrombin injection: 0.9% vs 0%, respectively [adjusted P<.001]). CONCLUSION: VCDs represented a safer and more effective alternative compared with manual compression for secondary femoral access-site hemostasis in patients undergoing TAVR procedures, and the Perclose VCD was associated with the lowest risk of vascular complications. Future randomized studies are warranted.


Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Dispositivos de Cierre Vascular , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Arteria Femoral/cirugía , Hemostasis , Técnicas Hemostáticas , Humanos , Resultado del Tratamiento
9.
Heart Rhythm ; 18(10): 1733-1740, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34082083

RESUMEN

BACKGROUND: The arrhythmic burden after discharge in patients with new-onset left bundle branch block (LBBB) undergoing transcatheter aortic valve replacement (TAVR) with the balloon-expandable SAPIEN 3 (S3) valve remains largely unknown. OBJECTIVE: The purpose of this study was to determine the incidence of late arrhythmias in patients with new-onset LBBB undergoing TAVR with the balloon-expandable S3 valve. METHODS: This was a multicenter, prospective study that included 104 consecutive TAVR patients with new-onset persistent LBBB following TAVR with the S3 valve. An implantable cardiac monitor (Reveal XT, Reveal LINQ) was implanted before discharge. The primary endpoint was the incidence of high-degree atrioventricular block or complete heart block (HAVB/CHB). RESULTS: A total of 40 patients (38.5%) had at least 1 significant arrhythmic event, leading to a treatment change in 17 (42.5%). Significant bradyarrhythmias occurred in 20 of 104 patients (19.2%) (34 HAVB/CHB episodes, 252 severe bradycardia episodes), with 10 of 20 patients (50%) exhibiting at least 1 episode of HAVB/CHB. Most HAVB/CHB episodes (60%) occurred within 4 weeks after discharge. Nine patients (8.7%) underwent permanent pacemaker implantation at 12 months based on the Reveal findings (6 HAVB/CHB, 3 severe bradycardia). CONCLUSION: S3 valve recipients with new-onset LBBB have a high arrhythmic burden, with more than one-third of patients exhibiting at least 1 significant arrhythmic episode within 12 months (HAVB/CHB in 10% of patients). About one-half of bradyarrhythmic events occurred within 4 weeks after discharge. These results should inform future strategies on the use of continuous electrocardiographic monitoring in TAVR S3 patients with new conduction disturbances following the procedure.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bloqueo de Rama/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Bloqueo de Rama/epidemiología , Bloqueo de Rama/fisiopatología , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Masculino , Estudios Prospectivos , Falla de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
J Clin Hypertens (Greenwich) ; 23(6): 1165-1175, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33942487

RESUMEN

Central aortic blood pressure could be helpful in the evaluation of patients with aortic stenosis (AS). The SphygmoCor XCEL device estimates central blood pressure (BP) measurement with its easy-to-use, operator-independent procedure. However, this device has not been properly validated against invasive measurement in patients with severe AS. We evaluated the relationship between cuff-brachial BP, transfer function-estimated and invasively measured central aortic pressure in patients with severe AS before and after transcatheter aortic valve replacement (TAVR). Agreement between techniques was analyzed and, according to the ARTERY Society recommendations, the minimum acceptable error was a mean difference ± SD ≤5 ± ≤8 mm Hg. A total of 94 patients with AS undergoing TAVR had simultaneous non-invasive and invasive measurements of central BP before and after the procedure. Before TAVR central systolic BP was in average slightly underestimated, though with wide variability, when using the default calibration of brachial-cuff SBP (mean difference ± SD, -3 ± 15 mm Hg), and after TAVR the degree of underestimation increased (mean difference ± SD, -9 ± 13 mm Hg). The agreement tended to improve for those patients with low aortic gradient stenosis compared to those with high gradient at baseline (mean difference ± SD, -2 ± 11 mm Hg vs. -4 ± 17, respectively, p = .3). The cuff-brachial systolic BP yielded numerically lower degree of agreement and weaker correlation with invasive measurements than SphygmoCor XCEL. In patients with severe AS the SphygmoCor XCEL cuff device, despite showing strong correlation, does not meet the ARTERY Society accuracy criteria for non-invasive measurement of central SBP.


Asunto(s)
Estenosis de la Válvula Aórtica , Hipertensión , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Presión Sanguínea , Determinación de la Presión Sanguínea , Humanos , Hipertensión/diagnóstico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
11.
Europace ; 23(2): 254-263, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-33083813

RESUMEN

AIMS: We determined the incidence and type of arrhythmias at 2-year follow-up in patients with new-onset persistent left bundle branch block (LBBB) following transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: Multicentre prospective study including 103 consecutive patients with new-onset persistent LBBB post-TAVR (SAPIEN XT/3: 53; CoreValve/Evolut R: 50). An implantable cardiac monitor (Reveal XT, Reveal Linq) was implanted before hospital discharge and patients had continuous monitoring for up to 2 years. Arrhythmic events were adjudicated in a central core lab. 1836 new arrhythmic events (tachyarrhythmias: 1655 and bradyarrhythmias: 181) occurred at 2 years. Of these, 283 (15%) occurred beyond 1 year (tachyarrhythmias 212, bradyarrhythmias 71) in 33 (36%) patients, without differences between valve type. Most late (>1 year) arrhythmic events were asymptomatic (94%) and led to a treatment change in 17 (19%) patients. A total of 71 late bradyarrhythmias [high-degree atrioventricular block (HAVB): 3, severe bradycardia: 68] were detected in 17 (21%) patients. At 2 years, 18 (17%) patients had received a permanent pacemaker (PPM) or implantable cardiac-defibrillator. PPM implantation due to HAVB predominated in the early phase post-TAVR, with only 1 HAVB event requiring PPM implantation after 1 year. CONCLUSION: Patients with new-onset LBBB post-TAVR exhibited a very high burden of arrhythmic events within the 2 years post-procedure. While new tachyarrhythmic events were homogeneously distributed over time, the vast majority of new HAVB episodes leading to PPM implantation occurred early after the procedure. These results should help to guide the management of this challenging group of patients. (clinicaltrials.gov: NCT02153307).


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/epidemiología , Bloqueo de Rama/etiología , Humanos , Estudios Prospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
EuroIntervention ; 16(4): e285-e292, 2020 07 17.
Artículo en Inglés | MEDLINE | ID: mdl-32207408

RESUMEN

AIMS: The aim of this study was to investigate the diagnostic performance of quantitative flow ratio (QFR) in assessing the physiological relevance of coronary lesions in the presence of severe aortic valve stenosis (SAS). METHODS AND RESULTS: A total of 115 SAS patients (138 coronary arteries) were included. Functional assessment of coronary stenoses was performed with fractional flow reserve (FFR) before transcatheter aortic valve implantation (TAVI). Subsequently, QFR was calculated at a central core laboratory, blinded to FFR results. The diagnostic yield of QFR was assessed using FFR as reference. Coronary stenoses were intermediate (diameter stenosis 48±10%, FFR 0.84 [0.77-0.89], QFR 0.82 [0.73-0.89]). Per-vessel sensitivity, specificity, area under the ROC curve and accuracy of QFR were 84% (95% CI: 71-92%), 80% (95% CI: 69-88%), 0.88 (95% CI: 0.82-0.93) and 81%, respectively. Diagnostic accuracy of QFR decreased significantly in patients with aortic valve area (AVA) <0.60 cm2. Diagnostic performance of QFR was superior to angiography in assessing the FFR-based functional significance (AUC 0.88 [95% CI: 0.82-0.93] vs 0.74 [95% CI: 0.66-0.81], respectively; p=0.0002). CONCLUSIONS: Compared with FFR, QFR has a good diagnostic yield and is superior to angiography in assessing the functional relevance of coronary lesions in SAS patients awaiting TAVI, particularly when AVA is ≥0.6 cm2.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico/fisiología , Enfermedad de la Arteria Coronaria , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Humanos , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
13.
Circ Cardiovasc Interv ; 13(3): e008609, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32089002

RESUMEN

BACKGROUND: Transfemoral approach has been commonly used as secondary access in transcatheter aortic valve replacement (TAVR). Scarce data exist on the use and potential clinical benefits of the transradial approach as secondary access during TAVR procedures. The objective of the study is to determine the occurrence of vascular complications (VC) and clinical outcomes according to secondary access (transfemoral versus transradial) in patients undergoing TAVR. METHODS: This was a multicenter study including 4949 patients who underwent TAVR (mean age, 81±8 years, mean Society of Thoracic Surgeons score, 4.9 [3.3-7.5]). Transfemoral and transradial approaches were used as secondary access in 4016 (81.1%) and 933 (18.9%) patients, respectively. The 30-day clinical events (vascular and bleeding complications, stroke, acute kidney injury, and mortality) were evaluated and defined according to Valve Academic Research Consortium-2 criteria. Clinical outcomes were analyzed according to the secondary access (transfemoral versus transradial) in the overall population and in a propensity score-matched population involving 2978 transfemoral and 928 transradial patients. RESULTS: Related-access VC occurred in 834 (16.9%) patients (major VC, 5.7%) and were related to the secondary access in 172 (3.5%) patients (major VC, 1.3%). The rate of VC related to the secondary access was higher in the transfemoral group (VC, 4.1% versus 0.9%, P<0.001; major VC, 1.6% versus 0%, P<0.001). In the propensity score-matched population, VC related to the secondary access remained higher in the transfemoral group (4.7% versus 0.9%, P<0.001; major VC, 1.8% versus 0%, P<0.001), which also exhibited a higher rate of major/life-threatening bleeding events (1.0% versus 0%, P<0.001). Significant differences between secondary access groups were observed regarding the rates of 30-day stroke (transfemoral: 3.1%, transradial: 1.6%; P=0.043), acute kidney injury (transfemoral: 9.9%, transradial: 5.7%; P<0.001), and mortality (transfemoral: 4.0%, transradial: 2.4%, P=0.047). CONCLUSIONS: The use of transradial approach as secondary access in TAVR procedures was associated with a significant reduction in vascular and bleeding complications and improved 30-day outcomes. Future randomized studies are warranted.


Asunto(s)
Cateterismo Periférico/métodos , Arteria Femoral , Arteria Radial , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Canadá , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Bases de Datos Factuales , Europa (Continente) , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Punciones , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
14.
EuroIntervention ; 16(3): 210-217, 2020 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-32011286

RESUMEN

AIMS: This study sought to investigate the prognostic effect of a protocol with optimisation targets for intravascular ultrasound (IVUS)-guided left main (LM) revascularisation. METHODS AND RESULTS: A protocol was prospectively applied for IVUS-guided LM revascularisation (IVUS-PRO group) including predefined optimisation targets. Using propensity score matching, we selected as control groups patients with angiography-guided PCI (ANGIO group) and IVUS-guided PCI (IVUS group) from a large multicentre registry. The primary endpoint was a composite of cardiac death, LM-related infarction and LM revascularisation at 12 months. In each group, 124 patients with comparable characteristics were included. The incidence of the primary outcome was significantly higher in the ANGIO group compared to the IVUS-PRO group (12.9% vs 4.8%, HR 0.35, 95% CI: 0.15 to 0.82, p=0.02), but not with respect to the IVUS group (12.9% vs 8%, HR 0.51, 95% CI: 0.20 to 1.22, p=0.1), driven by a lower rate of LM revascularisation (8% in the ANGIO group, 6.4% in the IVUS group and 3.2% in the IVUS-PRO group). IVUS-PRO resulted in being an independent risk predictor (HR 0.45, 95% CI: 0.15 to 0.98; p=0.041). CONCLUSIONS: IVUS guidance of LM stenting provides prognostic benefit with respect to the use of angiography alone, particularly when following a protocol with these predefined optimisation criteria.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Estenosis Coronaria/terapia , Intervención Coronaria Percutánea/métodos , Ultrasonografía Intervencional/métodos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Stents Liberadores de Fármacos , Humanos , Estudios Prospectivos , Resultado del Tratamiento
15.
Am J Cardiol ; 125(5): 795-802, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-31889524

RESUMEN

This study sought to determine, in patients with new-onset persistent left bundle branch block (NOP-LBBB) after transcatheter aortic valve implantation (TAVI), the incidence and factors associated with (i) LBBB recovery and (ii) permanent pacemaker implantation (PPI) at 1-year follow-up. This was a multicenter study including 153 patients (mean age: 81 ± 5 years, 56% of women) with NOP-LBBB post-TAVI (balloon-expandable valve in 112 patients). Delta PR (ΔPR) and delta QRS (ΔQRS) were defined as the difference in PR and QRS length between baseline and hospital discharge ECG, and the relative ΔPR and ΔQRS as absolute ΔPR and ΔQRS divided by baseline PR and QRS length, respectively. The patients had a clinical visit and 12-lead ECG at 1-year follow-up. LBBB recovery was observed in 50 patients (33%), and 14 patients (9%) had advanced conduction disturbances requiring PPI during the follow-up period. No clinical or ECG variables were associated with LBBB recovery, including prosthesis type (self- or balloon-expandable valve, p = 0.563), QRS width at baseline/discharge or absolute/relative ΔQRS (p >0.10 for all). The presence of atrial fibrillation at baseline (0.026), a longer PR interval at discharge (0.009), and a longer absolute and relative ΔPR (p = 0.002 and p = 0.004, respectively) were associated with an increased risk of PPI at 1-year follow-up. In conclusion, NOP-LBBB post-TAVI resolved in one-third of patients at 1-year follow-up, but no clinical or ECG variables were associated with LBBB recovery. Conversely, a nonsinus rhythm at baseline and a longer ΔPR were associated with an increased risk of PPI within the year after TAVI.


Asunto(s)
Válvula Aórtica/cirugía , Bloqueo de Rama/fisiopatología , Estimulación Cardíaca Artificial , Electrocardiografía , Complicaciones Posoperatorias/fisiopatología , Recuperación de la Función , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/epidemiología , Bloqueo de Rama/epidemiología , Bloqueo de Rama/terapia , Comorbilidad , Femenino , Humanos , Incidencia , Masculino , Marcapaso Artificial , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia
16.
JACC Cardiovasc Interv ; 12(12): 1175-1184, 2019 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-31129090

RESUMEN

OBJECTIVES: The aim of this study was to determine the impact of new-onset persistent (NOP) left bundle branch block (LBBB) on long-term (>2 year) outcomes after transcatheter aortic valve replacement (TAVR). BACKGROUND: The impact of NOP-LBBB after TAVR remains controversial and no data exist regarding long-term outcomes. METHODS: A total of 1,020 consecutive patients without pre-existing LBBB or permanent pacemaker implantation (PPI) undergoing TAVR were included. NOP-LBBB was defined as any new LBBB post-TAVR that persisted at hospital discharge. Follow-up clinical and echocardiographic data were obtained at a median of 3 years (interquartile range: 2 to 5 years) post-TAVR. RESULTS: NOP-LBBB occurred in 212 patients (20.1%) following TAVR. There were no differences between NOP-LBBB and no NOP-LBBB groups, except for a higher use of the self-expandable CoreValve system in the NOP-LBBB group (p < 0.001). At follow-up, there were no differences between NOP-LBBB and no NOP-LBBB groups in all-cause mortality (45.3% vs. 42.5%; adjusted hazard ratio [HR]:1.09; 95% confidence interval [CI]: 0.82 to 1.47; p = 0.54), cardiovascular mortality (14.2% vs. 14.4%; adjusted HR: 1.02; 95% CI: 0.56 to 1.87; p = 0.95), or heart failure rehospitalization (19.8% vs. 15.6%; adjusted HR: 1.44; 95% CI: 0.85 to 2.46; p = 0.18). NOP-LBBB was associated with an increased risk of permanent pacemaker implantation at follow-up (15.5% vs. 5.4%; adjusted HR: 2.45; 95% CI: 1.37 to 4.38; p = 0.002), with the highest risk within the first 12 months. Left ventricular ejection fraction increased over time in patients with no NOP-LBBB but slightly decreased in those with NOP-BBB (p < 0.001 for changes in left ventricular ejection fraction between groups). CONCLUSIONS: After a median follow-up of 3 years post-TAVR, NOP-LBBB was not associated with a higher mortality or heart failure rehospitalization. However, NOP-LBBB increased the risk of permanent pacemaker implantation and negatively impacted left ventricular function over time. These results should inform future efforts for improving the management of patients with NOP-LBBB post-TAVR.


Asunto(s)
Bloqueo de Rama/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Bloqueo de Rama/mortalidad , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial , Causas de Muerte , Progresión de la Enfermedad , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Readmisión del Paciente , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , España , Volumen Sistólico , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Función Ventricular Izquierda
17.
Cardiovasc Revasc Med ; 20(8): 705-710, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30414798

RESUMEN

OBJECTIVES: We investigated the safety and efficacy of the bioabsorbable polymer-coated, everolimus-eluting coronary stent (SYNERGY) stent in a real-world study population with acute coronary syndromes (ACS). BACKGROUND: A number of clinical trials support the overall efficacy and safety of the SYNERGY stent. However, a recent trial (TIDES-ACS) in the context of ACS reported worrying figures of infarction and definite/probable stent thrombosis in the SYNERGY control arm. METHODS: This is a multicenter registry (10 centers) including consecutive patients with ACS (unstable angina, non-ST elevated myocardial infarction, ST elevated myocardial infarction) who underwent percutaneous revascularization with the implantation of SYNERGY stent. The primary endpoint was the composite of cardiac death, myocardial infarction and target lesion revascularization at 12 months. RESULTS: A total of 1008 patients were included with age 65.4 ±â€¯14.8 years, 23.8% females and a 24.5% diabetics. Regarding presentation, a 15.2% with unstable angina, 43% with non-ST elevated myocardial infarction and 41.8% with ST elevated myocardial infarction. Primary outcome was met in 3% (7% in SYNERGY TIDES-ACS arm, P superiority <0.01 and 6.3% in OPTIMAX TIDES-ACS arm, P superiority <0.01). Cardiac death was 1.3% (1.6%, p = 0.8 and 0.5%, P superiority =0.1 respectively). Myocardial infarction was 1.6% (4.6%, p < 0.01 and 1.8%, P superiority = 0.9 respectively). Target lesion revascularization was 1% (3.4%, p < 0.01 and 5.4%, P superiority <0.01 respectively). Definite or probable thrombosis was 0.9% (2.8%, p ≤ 0.01 and 1.1%, P superiority = 0.8 respectively). CONCLUSIONS: The results of this registry show a very good safety and efficacy profile at 12 months for the SYNERGY stent in patients with ACS. SUMMARY: A recent trial (TIDES-ACS) in the context of acute coronary syndromes (ACS) reported worrying figures of infarction and definite/probable stent thrombosis in the SYNERGY stent control arm. We investigated the safety of SYNERGY stent in a real-world study population with ACS applying the same inclusion/exclusion criteria as used in the TIDES-ACS trial. Primary endpoint was the composite of cardiac death, myocardial infarction and TLR at 12 months. A total of 1008 patients have been included. Primary outcome was met in 3% (7% in SYNERGY TIDES-ACS arm, P superiority <0.01 and 6.3% in OPTIMAX TIDES-ACS arm, P superiority <0.01).


Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/terapia , Fármacos Cardiovasculares/administración & dosificación , Cromo , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Infarto del Miocardio sin Elevación del ST/terapia , Intervención Coronaria Percutánea/instrumentación , Platino (Metal) , Infarto del Miocardio con Elevación del ST/terapia , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Anciano , Anciano de 80 o más Años , Angina Inestable/diagnóstico por imagen , Angina Inestable/mortalidad , Angina Inestable/terapia , Fármacos Cardiovasculares/efectos adversos , Trombosis Coronaria/etiología , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Recurrencia , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/mortalidad , España , Factores de Tiempo , Resultado del Tratamiento
18.
JACC Cardiovasc Interv ; 11(15): 1495-1505, 2018 08 13.
Artículo en Inglés | MEDLINE | ID: mdl-30031719

RESUMEN

OBJECTIVES: The authors sought to determine: 1) the global arrhythmic burden; 2) the rate of arrhythmias leading to a treatment change; and 3) the incidence of high-degree atrioventricular block (HAVB) at 12-month follow-up in patients with new-onset persistent left bundle branch block (LBBB) following transcatheter aortic valve replacement (TAVR). BACKGROUND: Controversial data exist on the occurrence of significant arrhythmias in patients with LBBB post-TAVR. METHODS: This was a multicenter prospective study including 103 consecutive patients with new-onset persistent LBBB post-TAVR with the balloon-expandable SAPIEN XT/3 valve (n = 53), or the self-expanding CoreValve/Evolut R system (n = 50). An implantable cardiac monitor (Reveal XT, Reveal Linq) was implanted at 4 (3 to 6) days post-TAVR, and patients had continuous electrocardiogram monitoring for 12 months. All arrhythmic events were adjudicated in a central electrocardiography core lab. Primary endpoints were the incidence of arrhythmias leading to a treatment change, and the incidence of HAVB at 12-month follow-up. RESULTS: A total of 1,553 new arrhythmic events were detected in 44 patients (1,443 episodes of tachyarrhythmia in 26 patients [atrial fibrillation/flutter/atrial tachycardia: 1,427, ventricular tachycardia 16]; 110 episodes of bradyarrhythmia in 21 patients [HAVB 54, severe bradycardia 56]). All arrhythmic events were silent in 34 patients (77%), the arrhythmic event led to a treatment change in 19 patients (18%), and 11 patients (11%) required pacemaker or implantable cardioverter-defibrillator implantation (due to HAVB, severe bradycardia, or ventricular tachycardia episodes in 9, 1, and 1 patient, respectively). A total of 12 patients died at 1-year follow-up, 1 from sudden death. CONCLUSIONS: A high incidence of arrhythmic events was observed at 1-year follow-up in close to one-half of the patients with LBBB post-TAVR. Significant bradyarrhythmias occurred in one-fifth of the patients, and PPM was required in nearly one-half of them. These data support the use of a cardiac monitoring device for close follow-up and expediting the initiation of treatment in this challenging group of patients. (Ambulatory Electrocardiographic Monitoring for the Detection of High-Degree Atrio-Ventricular Block in Patients With New-onset PeRsistent LEft Bundle Branch Block After Transcatheter Aortic Valve Implantation [MARE study]: NCT02153307).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas/diagnóstico , Bloqueo de Rama/diagnóstico , Electrocardiografía Ambulatoria , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/epidemiología , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Bloqueo de Rama/epidemiología , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Canadá/epidemiología , Europa (Continente)/epidemiología , Femenino , Frecuencia Cardíaca , Humanos , Incidencia , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología
19.
JACC Cardiovasc Interv ; 11(3): 301-310, 2018 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-29413244

RESUMEN

OBJECTIVES: This study sought to evaluate the long-term clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR). BACKGROUND: Conduction disturbances leading to PPI are common following TAVR. However, no data exist regarding the impact of PPI on long-term outcomes post-TAVR. METHODS: This was a multicenter study including a total of 1,629 patients without prior PPI undergoing TAVR (balloon- and self-expandable valves in 45% and 55% of patients, respectively). Follow-up clinical, echocardiographic, and pacing data were obtained at a median of 4 years (interquartile range: 3 to 5 years) post-TAVR. RESULTS: PPI was required in 322 (19.8%) patients within 30 days post-TAVR (26.9% and 10.9% in patients receiving self- and balloon-expandable CoreValve and Edwards systems, respectively). Up to 86% of patients with PPI exhibited pacing >1% of the time during follow-up (>40% pacing in 51% of patients). There were no differences between patients with and without PPI in total mortality (48.5% vs. 42.9%; adjusted hazard ratio [HR]: 1.15; 95% confidence interval [CI]: 0.95 to 1.39; p = 0.15) and cardiovascular mortality (14.9% vs. 15.5%, adjusted HR: 0.93; 95% CI: 0.66 to 1.30; p = 0.66) at follow-up. However, patients with PPI had higher rates of rehospitalization due to heart failure (22.4% vs. 16.1%; adjusted HR: 1.42; 95% CI: 1.06 to 1.89; p = 0.019), and the combined endpoint of mortality or heart failure rehospitalization (59.6% vs. 51.9%; adjusted HR: 1.25; 95% CI: 1.05 to 1.48; p = 0.011). PPI was associated with lesser improvement in LVEF over time (p = 0.051 for changes in LVEF between groups), particularly in patients with reduced LVEF before TAVR (p = 0.005 for changes in LVEF between groups). CONCLUSIONS: The need for PPI post-TAVR was frequent and associated with an increased risk of heart failure rehospitalization and lack of LVEF improvement, but not mortality, after a median follow-up of 4 years. Most patients with new PPI post-TAVR exhibited some degree of pacing activity at follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Valvuloplastia con Balón/efectos adversos , Femenino , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Prótesis Valvulares Cardíacas , Humanos , Italia , Masculino , Readmisión del Paciente , Estudios Prospectivos , Diseño de Prótesis , Quebec , Factores de Riesgo , España , Volumen Sistólico , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Función Ventricular Izquierda
20.
Catheter Cardiovasc Interv ; 90(2): E25-E30, 2017 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-27807948

RESUMEN

OBJECTIVES: We sought to compare the procedural implications of using bioresorbable everolimus-eluting scaffolds (BVS) and Pt-Cr everolimus-eluting stent with abluminal bioabsorbable polymer (Synergy). BACKGROUND: There are important differences in the respective platforms, which could impact on procedural performance, complications and outcomes. METHODS: A prospective, randomized single center study including consecutive patients in stable clinical condition and with lesions amenable to be treated with BVS according to predefined criteria. Patients were randomized to either treatment with BVS or Synergy. All procedural data were collected and 12 months clinical follow up conducted. Primary objectives were fluoroscopy time, median dose-area product, contras agent volumen, and peri-procedural troponin release. RESULTS: A total of 200 patients were included, 100 in BVS group and 100 in Synergy group. No significant differences were observed in baseline clinical and angiographic characteristics. Predilatation (97.6 vs. 25.4%; P < 0.001), postdilatation (64.8 vs. 38.4%: P < 0.01), and use of 2 wires (20.8 vs. 10%; P = 0.02) were more frequent with BVS. The BVS group showed a significant increase in fluoroscopy time (18%), dose-area product (20%), and contrast volume (10%). Post-procedural increase of creatinine was similar and amount of TnI release was significantly higher with BVS but incidence of peri-procedural infarction was comparable. Clinical outcomes at 12 months were similar with definite thrombosis being 1% with BVS and 0% with Synergy. CONCLUSIONS: The use of BVS in comparison with the Synergy stent in a similar lesional setting is associated with a higher use of resources in the procedure, more radiation, and higher TnI release. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Anciano , Fármacos Cardiovasculares/efectos adversos , Medios de Contraste/administración & dosificación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Trombosis Coronaria/etiología , Everolimus/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Dosis de Radiación , Exposición a la Radiación , Radiografía Intervencional , Factores de Riesgo , España , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA